冷库安装的过程中,冷库配电箱的使用是一个非常重要的内容。冷库安装之后,冷库配电箱外面的配线必须要使用正确的方法来进行保护,比如说钢管软管这一些配线,我们尽量放在不容易受损的地方,否则就可能会导致冷库配电箱的配线受到不必要的损害。同时,配电箱机床之间的电源线尽量放置在桥架中间,桥架也需要使用底座来起到支撑的作用,建议在使用桥架的时候,千万不可以和地面直接接触。
In the process of cold storage installation, the use of cold storage distribution box is a very important content. After the cold storage is installed, the distribution cables outside the cold storage distribution box must be protected by the correct method. For example, the distribution cables such as steel tube hose should be placed in the place where it is not easy to be damaged. Otherwise, it may cause unnecessary damage to the distribution cables of the cold storage distribution box. At the same time, the power line between the machine tools of distribution box is placed in the middle of the bridge as far as possible, and the bridge also needs to use the base to play a supporting role.
冷库配电箱外面的配管也需要做到统一,这也是冷库安装后的一个重要内容。如果存在不统一的现象,那么在后期的使用中,经常性都会出现故障问题,浪费我们不必要的维修费用。
The distribution pipes outside the distribution box of the cold storage also need to be unified, which is also an important content after the installation of the cold storage. If there is a phenomenon of non-uniformity, then in the later use, frequent problems will occur, waste our unnecessary maintenance costs.
冷库安装时,对于配电箱包装机或者是其他加热设备的连接都需要重视起来,布线的时候,需要远离靠近加热的地方,接线尽量放置在连接箱里面,加热器的连接线尽量使用玻璃或者是陶管电线,为了安全不可以使用可燃性电线。
Cold storage installation, for distribution box packaging machine or other heating equipment need to pay attention to the connection, wiring, need to stay away from the heating place, wiring as far as possible in the connection box, heater wiring as far as possible to use glass or pottery wire, in order to be safe not to use combustible electricity Line.
冷库配电箱外面所有的电线在链接的时候都需要放在连接箱内,这也是冷库安装过程中的重要内容,此外,连接线的中间不可以有接头。
All the wires outside the cold storage distribution box need to be placed in the connection box when they are connected, which is also an important part of the cold storage installation process. In addition, there must be no connectors in the middle of the connection line.
冷库配电箱所有的连接箱,电线入口的保护等级,全部都需要在IP55以上的标准。
All connection boxes of cold storage distribution boxes and protection levels of wire entrances all require standards above IP55.
中继合端子台尽量使用两根电线进行链接,如果需要链接三根以上的电线,尽量设置其他的端子台,否则也会影响到配电箱的正常使用。
If more than three wires need to be linked, try to set up other terminals, otherwise it will affect the normal use of distribution boxes.
感应器在布线的时候如果放置在容易损害的地方,尽量使用软管来起到保护的作用,软管的使用,尽量直接安放在感应器的根部,这一个内容也是冷库安装时需要重视的。
If the sensor is placed in a vulnerable place when wiring, try to use hose to play a protective role, the use of hose, as far as possible directly placed at the root of the sensor, this content is also cold storage installation need to pay attention to.
同时,冷库安装之后,对于配电箱的正常使用,需要经常性进行检查,一旦出现隐患,必须要在第一时间进行处理,否则对于正常的使用会造成影响,甚至可能会造成经济损失。
At the same time, the cold storage installation, for the normal use of distribution boxes, need to be checked regularly, once there are hidden dangers, must be dealt with at the first time, otherwise for the normal use will affect, and may even cause economic losses.